﻿{"id":438,"date":"2020-03-05T13:48:30","date_gmt":"2020-03-05T12:48:30","guid":{"rendered":"http:\/\/wpd.ugr.es\/~ecsens\/?p=438"},"modified":"2020-09-10T10:54:04","modified_gmt":"2020-09-10T08:54:04","slug":"ecsens-informa-corona","status":"publish","type":"post","link":"https:\/\/wpd.ugr.es\/~ecsens\/ecsens-informa-corona\/","title":{"rendered":"Investigadores de la UGR dise\u00f1an un sensor que permite detectar problemas de ri\u00f1\u00f3n al analizar la orina"},"content":{"rendered":"<p>[et_pb_section fb_built=\u00bb1&#8243; _builder_version=\u00bb4.3.4&#8243; background_color=\u00bb#FFFFFF\u00bb custom_padding=\u00bb28px|||||\u00bb][et_pb_row column_structure=\u00bb2_3,1_3&#8243; _builder_version=\u00bb4.3.4&#8243;][et_pb_column type=\u00bb2_3&#8243; _builder_version=\u00bb4.3.4&#8243;][et_pb_text _builder_version=\u00bb4.3.4&#8243;]<\/p>\n<ul>\n<li><strong>Este nuevo sensor permite determinar el nivel de creatinina (un metabolito presente en la orina, cuya la cantidad se usa para diagnosticar el funcionamiento del ri\u00f1\u00f3n) de manera r\u00e1pida y sencilla en un laboratorio<\/strong><\/li>\n<li><strong>En la actualidad, la mayor\u00eda de los laboratorios utilizan una t\u00e9cnica del a\u00f1o 1886, dise\u00f1ada por el pat\u00f3logo alem\u00e1n Max Jaff\u00e9, para detectar este metabolito<\/strong><\/li>\n<\/ul>\n<p>Investigadores de la Universidad de Granada (UGR) han dise\u00f1ado un nuevo sensor que permite determinar el nivel de creatinina (un metabolito presente en la orina, cuya la cantidad se usa para diagnosticar el funcionamiento del ri\u00f1\u00f3n) de manera r\u00e1pida y sencilla en el laboratorio.<\/p>\n<p>En la actualidad, la determinaci\u00f3n del nivel de creatinina en orina se realiza de forma rutinaria en el laboratorio de an\u00e1lisis cl\u00ednico. Habitualmente se utiliza el m\u00e9todo puesto a punto por el pat\u00f3logo alem\u00e1n Max Jaff\u00e9 en 1886, siendo el \u00fanico m\u00e9todo de an\u00e1lisis cl\u00ednico de esa \u00e9poca que a\u00fan se usa en el laboratorio. Este m\u00e9todo presenta diversos problemas, como es su falta de especificidad, aunque es un m\u00e9todo r\u00e1pido y barato. Esto justifica que sea de inter\u00e9s el desarrollo de nuevos procedimientos para la determinaci\u00f3n de creatinina.<\/p>\n<p>La concentraci\u00f3n normal de creatinina en orina se encuentra entre 0,7 y 1,2 mg\/dL y en caso de que sea superior o inferior, puede indicar alg\u00fan tipo de problema renal y tambi\u00e9n se\u00f1alar la p\u00e9rdida o destrucci\u00f3n de tejido muscular.<\/p>\n<h2><strong>Sensor de un solo uso<\/strong><\/h2>\n<p>En el grupo de investigaci\u00f3n ECsens, perteneciente al departamento de Qu\u00edmica Anal\u00edtica de la UGR, han desarrollado un sensor de un solo uso que permite determinar la concentraci\u00f3n de creatinina en muestras de orina de manera r\u00e1pida y sencilla en el laboratorio, utilizando peque\u00f1os vol\u00famenes de orina y reactivos.<\/p>\n<p>El sensor es una membrana de PVC (cloruro de polivinilo) que contiene los reactivos necesarios para llevar a cabo la determinaci\u00f3n. Al introducir el sensor en la orina, este cambia de color de amarillo a naranja, dependiendo de la concentraci\u00f3n de creatina en la muestra. En este caso, la respuesta de la membrana no se ve afectada por otros componentes de la orina, como ocurre en el m\u00e9todo de Jaff\u00e9, gracias al uso de una mol\u00e9cula llamada calix[4]pirrol, capaz de reconocer espec\u00edficamente a la creatinina.<\/p>\n<p>El sensor puesto a punto permite calcular la concentraci\u00f3n de creatinina en orina dentro de los niveles habituales con una precisi\u00f3n del 6%, simplemente introduciendo la membrana y esperando 3 minutos antes de medir el color. Este m\u00e9todo es respetuoso con el medio ambiente, al necesitar muy peque\u00f1a cantidad de reactivos y generar menos residuos.<\/p>\n<p>Este trabajo ha sido publicado por la revista<span>\u00a0<\/span><em>ACS Sensors<\/em><span>\u00a0<\/span>de la American Chemical Society.<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_text][\/et_pb_column][et_pb_column type=\u00bb1_3&#8243; _builder_version=\u00bb4.3.4&#8243;][et_pb_image src=\u00bbhttp:\/\/wpd.ugr.es\/~ecsens\/wp-content\/uploads\/2020\/09\/quimica-analitica-300&#215;225.jpg\u00bb _builder_version=\u00bb4.3.4&#8243;][\/et_pb_image][et_pb_image src=\u00bbhttp:\/\/wpd.ugr.es\/~ecsens\/wp-content\/uploads\/2020\/09\/ecsens-investigadores-300&#215;169.jpg\u00bb show_in_lightbox=\u00bbon\u00bb align=\u00bbcenter\u00bb force_fullwidth=\u00bbon\u00bb admin_label=\u00bbLos investigadores de la UGR que han llevado a cabo este trabajo.\u00bb _builder_version=\u00bb4.3.4&#8243; custom_margin=\u00bb||9px|||\u00bb][\/et_pb_image][et_pb_text _builder_version=\u00bb4.3.4&#8243; custom_margin=\u00bb0px||||false|false\u00bb]<\/p>\n<p style=\"text-align: right;\"><em>Investigadores de ECsens.<\/em><\/p>\n<p>[\/et_pb_text][et_pb_image src=\u00bbhttp:\/\/wpd.ugr.es\/~ecsens\/wp-content\/uploads\/2020\/09\/INFOGRAFIA-DE-LA-MEMBRANA-300&#215;161.jpg\u00bb show_in_lightbox=\u00bbon\u00bb align=\u00bbcenter\u00bb force_fullwidth=\u00bbon\u00bb admin_label=\u00bbLos investigadores de la UGR que han llevado a cabo este trabajo.\u00bb _builder_version=\u00bb4.3.4&#8243; custom_margin=\u00bb||9px|||\u00bb][\/et_pb_image][et_pb_text _builder_version=\u00bb4.3.4&#8243; custom_margin=\u00bb0px||||false|false\u00bb]<\/p>\n<p style=\"text-align: right;\"><em>Ilustraci\u00f3n de la membrana.<\/em><\/p>\n<p>[\/et_pb_text][et_pb_divider color=\u00bb#000000&#8243; divider_weight=\u00bb3px\u00bb _builder_version=\u00bb4.3.4&#8243;][\/et_pb_divider][et_pb_toggle title=\u00bbdoi\u00bb icon_color=\u00bb#0C71C3&#8243; use_icon_font_size=\u00bbon\u00bb icon_font_size=\u00bb18px\u00bb _builder_version=\u00bb4.3.4&#8243; title_font_size=\u00bb14px\u00bb closed_title_font_size=\u00bb14px\u00bb text_orientation=\u00bbleft\u00bb custom_margin=\u00bb||10px|||\u00bb]<\/p>\n<p>10.1021\/acssensors.8b01378<\/p>\n<p>[\/et_pb_toggle][et_pb_toggle title=\u00bbENLACES DE INTERES\u00bb icon_color=\u00bb#0C71C3&#8243; use_icon_font_size=\u00bbon\u00bb icon_font_size=\u00bb18px\u00bb _builder_version=\u00bb4.3.4&#8243; title_font_size=\u00bb14px\u00bb closed_title_font_size=\u00bb14px\u00bb text_orientation=\u00bbleft\u00bb custom_margin=\u00bb||10px|||\u00bb hover_enabled=\u00bb0&#8243;]<\/p>\n<p><a href=\"https:\/\/scholar.google.es\/scholar?hl=es&amp;as_sdt=0%2C5&amp;q=Ionophore-based+optical+sensor+for+urine+creatinine+detection&amp;btnG=\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"color: #3366ff;\"><strong>Google Scholar<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/pubs.acs.org\/doi\/10.1021\/acssensors.8b01378\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/pubs.acs.org\/doi\/10.1021\/acssensors.8b0137810.1021\/acssensors.8b01378<\/a><\/p>\n<p>[\/et_pb_toggle][et_pb_toggle title=\u00bbReferencia bibliogr\u00e1fica\u00bb icon_color=\u00bb#0C71C3&#8243; use_icon_font_size=\u00bbon\u00bb icon_font_size=\u00bb18px\u00bb _builder_version=\u00bb4.3.4&#8243; title_font_size=\u00bb14px\u00bb closed_title_font_size=\u00bb14px\u00bb text_orientation=\u00bbleft\u00bb custom_margin=\u00bb||10px|||\u00bb]<\/p>\n<p><em>Ionophore-based optical sensor for urine creatinine detection<\/em><\/p>\n<p>Miguel M. Erenas, Inmaculada Ortiz-G\u00f3mez, Ignacio de Orbe-Pay\u00e1, Daniel Hern\u00e1ndez-Alonso, Pablo Ballester, Pascal Blondeau, Francisco J. Andrade, Alfonso Salinas-Castillo, Luis Ferm\u00edn Capit\u00e1n-Vallvey.<\/p>\n<p>ACS Sensors 4, 2, 421-426 (2019)<\/p>\n<p>DOI: 10.1021\/acssensors.8b01378<\/p>\n<p>[\/et_pb_toggle][et_pb_toggle title=\u00bbContacto\u00bb icon_color=\u00bb#0C71C3&#8243; use_icon_font_size=\u00bbon\u00bb icon_font_size=\u00bb18px\u00bb _builder_version=\u00bb4.3.4&#8243; title_font_size=\u00bb14px\u00bb closed_title_font_size=\u00bb14px\u00bb text_orientation=\u00bbleft\u00bb custom_margin=\u00bb||10px|||\u00bb hover_enabled=\u00bb0&#8243;]<\/p>\n<p><strong>Miguel Erenas Rodr\u00edguez<\/strong><\/p>\n<p>Departamento de Qu\u00edmica Anal\u00edtica de la UGR<\/p>\n<p><strong>Correo electr\u00f3nico:<\/strong> erenas@ugr.es<\/p>\n<p>[\/et_pb_toggle][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[et_pb_section fb_built=\u00bb1&#8243; _builder_version=\u00bb4.3.4&#8243; background_color=\u00bb#FFFFFF\u00bb custom_padding=\u00bb28px|||||\u00bb][et_pb_row column_structure=\u00bb2_3,1_3&#8243; _builder_version=\u00bb4.3.4&#8243;][et_pb_column type=\u00bb2_3&#8243; _builder_version=\u00bb4.3.4&#8243;][et_pb_text _builder_version=\u00bb4.3.4&#8243;] Este nuevo sensor permite determinar el nivel de creatinina (un metabolito presente en la orina, cuya la cantidad se usa para diagnosticar el funcionamiento del ri\u00f1\u00f3n) de manera r\u00e1pida y sencilla en un laboratorio En la actualidad, la mayor\u00eda de los laboratorios utilizan una t\u00e9cnica [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":870,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":""},"categories":[5],"tags":[],"_links":{"self":[{"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/posts\/438"}],"collection":[{"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/comments?post=438"}],"version-history":[{"count":21,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/posts\/438\/revisions"}],"predecessor-version":[{"id":957,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/posts\/438\/revisions\/957"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/media\/870"}],"wp:attachment":[{"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/media?parent=438"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/categories?post=438"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/tags?post=438"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}