﻿{"id":544,"date":"2020-09-04T12:32:48","date_gmt":"2020-09-04T10:32:48","guid":{"rendered":"http:\/\/wpd.ugr.es\/~ecsens\/?p=544"},"modified":"2020-09-10T12:17:22","modified_gmt":"2020-09-10T10:17:22","slug":"news-ecsens-5","status":"publish","type":"post","link":"https:\/\/wpd.ugr.es\/~ecsens\/news-ecsens-5\/","title":{"rendered":"Calcula la concentraci\u00f3n de potasio en agua, de creatinina en orina o de glucosa en sangre usando un \u2018smartphone\u2019"},"content":{"rendered":"<p>[et_pb_section fb_built=\u00bb1&#8243; _builder_version=\u00bb4.3.4&#8243; background_color=\u00bb#FFFFFF\u00bb custom_padding=\u00bb28px|||||\u00bb][et_pb_row column_structure=\u00bb2_3,1_3&#8243; _builder_version=\u00bb4.3.4&#8243;][et_pb_column type=\u00bb2_3&#8243; _builder_version=\u00bb4.3.4&#8243;][et_pb_text _builder_version=\u00bb4.3.4&#8243;]<\/p>\n<p>El uso de dispositivos Point-of -Care (POC) est\u00e1 cada vez est\u00e1 mas extendido en el \u00e1rea del an\u00e1lisis cl\u00ednico, ya que permiten analizar muestras de manera r\u00e1pida y sencilla, sobre todo, sin necesidad de transportar la muestra al laboratorio, porque se puede hacer el an\u00e1lisis \u2018in situ\u2019. Adem\u00e1s, gracias a estas caracter\u00edsticas, el an\u00e1lisis puede ser realizado por personal especializado, as\u00ed como por el propio usuario que necesita llevar a cabo el control de alg\u00fan par\u00e1metro cl\u00ednico.<\/p>\n<p>El desarrollo de estos dispositivos se centra sobre todo la puesta a punto de nuevas qu\u00edmicas de reconocimiento que permitan monitorizar los compuestos de inter\u00e9s de la manera m\u00e1s r\u00e1pida, sencilla y fiable posible. Adem\u00e1s, debe tenerse en cuenta otros factores relacionados con lo que se conoce como \u2018qu\u00edmica verde\u2019, que busca\u00a0que los dispositivos desarrollados generen la menor cantidad de residuos posibles, as\u00ed como el uso de materiales lo menos contaminantes posible.<\/p>\n<p>En el grupo de investigaci\u00f3n ECsens de la Universidad de Granada (@ECsens_ugr) trabajan en el desarrollo de dispositivos microflu\u00eddicos colorim\u00e9tricos usando como soporte hilo de algod\u00f3n.<\/p>\n<p><strong>Un m\u00e9todo sencillo, r\u00e1pido y fiable<\/strong><\/p>\n<p>A lo largo de los \u00faltimos a\u00f1os, los investigadores de la UGR han desarrollado diversos dispositivos basados en este soporte que, combinados con un tel\u00e9fono m\u00f3vil (smartphone) para fotografiar el dispositivo, analizar el color y calcular la concentraci\u00f3n, permitir\u00edan al usuario analizar una muestra de forma sencilla, r\u00e1pida y fiable. Por ejemplo, la concentraci\u00f3n de potasio en agua, de creatinina en orina o de glucosa en sangre a\u00f1adiendo tan solo un peque\u00f1o volumen de muestra en el dispositivo y obteniendo los resultados en segundos.<\/p>\n<p>El uso del hilo de algod\u00f3n como soporte tiene\u00a0 varias ventajas. Por un lado, gracias a sus propiedades capilares y a su morfolog\u00eda, es posible dise\u00f1ar dispositivos muy f\u00e1ciles de usar, siendo s\u00f3lo necesario a\u00f1adir un peque\u00f1o volumen de muestra, que avanza por capilaridad desde la zona de muestreo a la de reconocimiento donde aparecer\u00e1 un color que depende de la concentraci\u00f3n de compuesto a analizar. El dispositivo contiene todos los reactivos necesarios para llevar a cabo la determinaci\u00f3n, con tiempos de reacci\u00f3n muy cortos (10 \u2013 60 segundos).<\/p>\n<p>Por otro lado, el uso del hilo permite desarrollar dispositivos que necesitan muy peque\u00f1os vol\u00famenes de reactivos y muestra (normalmente vol\u00famenes entre 1-10 microlitros). El empleo de muy peque\u00f1as cantidades de reactivos, junto con el car\u00e1cter biodegradable del algod\u00f3n, hace que el sistema anal\u00edtico sea muy poco contaminante.<\/p>\n<p>[\/et_pb_text][et_pb_image src=\u00bbhttp:\/\/wpd.ugr.es\/~ecsens\/wp-content\/uploads\/2020\/09\/ecsens-quimica-investigacion.jpg\u00bb force_fullwidth=\u00bbon\u00bb _builder_version=\u00bb4.3.4&#8243;][\/et_pb_image][et_pb_text _builder_version=\u00bb4.3.4&#8243; custom_margin=\u00bb0px||||false|false\u00bb]<\/p>\n<p style=\"text-align: right;\"><em>El grupo de investigaci\u00f3n de la UGR que ha llevado a cabo este trabajo.<\/em><\/p>\n<p>[\/et_pb_text][\/et_pb_column][et_pb_column type=\u00bb1_3&#8243; _builder_version=\u00bb4.3.4&#8243;][et_pb_image src=\u00bbhttp:\/\/wpd.ugr.es\/~ecsens\/wp-content\/uploads\/2020\/09\/quimica-analitica-300&#215;225.jpg\u00bb _builder_version=\u00bb4.3.4&#8243;][\/et_pb_image][et_pb_image src=\u00bbhttp:\/\/wpd.ugr.es\/~ecsens\/wp-content\/uploads\/2020\/09\/potasio2-300&#215;199.jpg\u00bb show_in_lightbox=\u00bbon\u00bb align=\u00bbcenter\u00bb force_fullwidth=\u00bbon\u00bb admin_label=\u00bbLos investigadores de la UGR que han llevado a cabo este trabajo.\u00bb _builder_version=\u00bb4.3.4&#8243; custom_margin=\u00bb||9px|||\u00bb][\/et_pb_image][et_pb_image src=\u00bbhttp:\/\/wpd.ugr.es\/~ecsens\/wp-content\/uploads\/2020\/09\/potasio3-300&#215;222.jpg\u00bb show_in_lightbox=\u00bbon\u00bb align=\u00bbcenter\u00bb force_fullwidth=\u00bbon\u00bb admin_label=\u00bbLos investigadores de la UGR que han llevado a cabo este trabajo.\u00bb _builder_version=\u00bb4.3.4&#8243; custom_margin=\u00bb||9px|||\u00bb][\/et_pb_image][et_pb_image src=\u00bbhttp:\/\/wpd.ugr.es\/~ecsens\/wp-content\/uploads\/2020\/09\/potasio-300&#215;268.jpg\u00bb show_in_lightbox=\u00bbon\u00bb align=\u00bbcenter\u00bb force_fullwidth=\u00bbon\u00bb admin_label=\u00bbLos investigadores de la UGR que han llevado a cabo este trabajo.\u00bb _builder_version=\u00bb4.3.4&#8243; custom_margin=\u00bb||9px|||\u00bb][\/et_pb_image][et_pb_text _builder_version=\u00bb4.3.4&#8243; custom_margin=\u00bb0px||||false|false\u00bb]<\/p>\n<p style=\"text-align: right;\"><em>Dispositivos para la determinaci\u00f3n de potasio en agua, creatinina en orina y glucosa en sangre..<\/em><\/p>\n<p>[\/et_pb_text][et_pb_divider color=\u00bb#000000&#8243; divider_weight=\u00bb3px\u00bb _builder_version=\u00bb4.3.4&#8243;][\/et_pb_divider][et_pb_toggle title=\u00bbdoi\u00bb icon_color=\u00bb#0C71C3&#8243; use_icon_font_size=\u00bbon\u00bb icon_font_size=\u00bb18px\u00bb _builder_version=\u00bb4.3.4&#8243; title_font_size=\u00bb14px\u00bb closed_title_font_size=\u00bb14px\u00bb text_orientation=\u00bbleft\u00bb custom_margin=\u00bb||10px|||\u00bb]<\/p>\n<ul>\n<li><a href=\"https:\/\/doi.org\/10.1016\/j.snb.2019.127407\" target=\"_blank\" rel=\"noopener noreferrer\">10.1016\/j.snb.2019.127407<\/a><\/li>\n<li><a href=\"https:\/\/doi.org\/10.1016\/j.bios.2019.04.024\" target=\"_blank\" rel=\"noopener noreferrer\">10.1016\/j.bios.2019.04.024<\/a><\/li>\n<\/ul>\n<p>[\/et_pb_toggle][et_pb_toggle title=\u00bbReferencia bibliogr\u00e1fica\u00bb icon_color=\u00bb#0C71C3&#8243; use_icon_font_size=\u00bbon\u00bb icon_font_size=\u00bb18px\u00bb _builder_version=\u00bb4.3.4&#8243; title_font_size=\u00bb14px\u00bb closed_title_font_size=\u00bb14px\u00bb text_orientation=\u00bbleft\u00bb custom_margin=\u00bb||10px|||\u00bb]<\/p>\n<p>Arroyo, M. J.; Erenas, M. M.; Orbe-pay\u00e1, I. De; Cantrell, K.; Dobado, J. A.; Ballester, P.; Blondeau, P.; Salinas-castillo, A.; Capit\u00e1n-vallvey, L. F. Thread Based Microfluidic Platform for Urinary Creatinine Analysis. Sensors Actuators B. Chem.2020, 305, 127407<span>\u00a0<\/span><a href=\"https:\/\/doi.org\/10.1016\/j.snb.2019.127407\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/doi.org\/10.1016\/j.snb.2019.127407<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>Erenas, M. M.; Carrillo-Aguilera, B.; Cantrell, K.; Gonzalez-Chocano, S.; Perez de Vargas Sansalvador, I. M.; de Orbe-Pay\u00e1, I.; Capitan-Vallvey, L. F. Real Time Monitoring of Glucose in Whole Bloodby Smartphone. Biosens. Bioelectron.2019, 136 (March), 47\u201352.<span>\u00a0<\/span><a href=\"https:\/\/doi.org\/10.1016\/j.bios.2019.04.024\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/doi.org\/10.1016\/j.bios.2019.04.024<\/a><\/p>\n<p>[\/et_pb_toggle][et_pb_toggle title=\u00bbContacto\u00bb icon_color=\u00bb#0C71C3&#8243; use_icon_font_size=\u00bbon\u00bb icon_font_size=\u00bb18px\u00bb _builder_version=\u00bb4.3.4&#8243; title_font_size=\u00bb14px\u00bb closed_title_font_size=\u00bb14px\u00bb text_orientation=\u00bbleft\u00bb custom_margin=\u00bb||10px|||\u00bb]<\/p>\n<p><strong>Miguel Erenas Rodr\u00edguez<\/strong><\/p>\n<p>Departamento de Qu\u00edmica Anal\u00edtica de la UGR<\/p>\n<p><strong>Correo electr\u00f3nico:<\/strong> erenas@ugr.es<\/p>\n<p>[\/et_pb_toggle][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[et_pb_section fb_built=\u00bb1&#8243; _builder_version=\u00bb4.3.4&#8243; background_color=\u00bb#FFFFFF\u00bb custom_padding=\u00bb28px|||||\u00bb][et_pb_row column_structure=\u00bb2_3,1_3&#8243; _builder_version=\u00bb4.3.4&#8243;][et_pb_column type=\u00bb2_3&#8243; _builder_version=\u00bb4.3.4&#8243;][et_pb_text _builder_version=\u00bb4.3.4&#8243;] El uso de dispositivos Point-of -Care (POC) est\u00e1 cada vez est\u00e1 mas extendido en el \u00e1rea del an\u00e1lisis cl\u00ednico, ya que permiten analizar muestras de manera r\u00e1pida y sencilla, sobre todo, sin necesidad de transportar la muestra al laboratorio, porque se puede hacer el an\u00e1lisis [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":928,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"Lorem ipsum dolor sit amet, consectetur adipiscing elit. Sed ullamcorper nisl libero, eget facilisis tortor laoreet eu. Duis congue mi in nunc scelerisque, in placerat mauris maximus. Duis interdum consequat augue, sit amet laoreet erat sollicitudin ac. Praesent sit amet malesuada nunc, vel convallis augue. Nullam vel libero ipsum. Pellentesque habitant morbi tristique senectus et netus et malesuada fames ac turpis egestas. Nam pulvinar consequat tortor, at lobortis lacus vulputate eget. Aliquam molestie venenatis augue, in luctus lacus aliquam vitae. Vivamus sed elit ante. Cras at felis sit amet enim laoreet pharetra. Pellentesque at purus commodo, laoreet dolor vitae, blandit ligula.\r\n\r\nSed pharetra orci non nunc rutrum ultricies. Vestibulum iaculis dolor dui, sit amet placerat sapien luctus eget. Curabitur est velit, porttitor nec imperdiet et, tincidunt et nisl. Duis lacinia tristique eros a commodo. Integer nec tincidunt lectus, et efficitur odio. Aliquam id egestas dui. Phasellus tempor a tortor eget aliquam. Sed ligula risus, dictum ut fringilla sed, vestibulum sit amet neque. Pellentesque habitant morbi tristique senectus et netus et malesuada fames ac turpis egestas. Aenean volutpat id quam in gravida. Cras libero purus, commodo in viverra sit amet, auctor quis erat. In congue, ligula sit amet efficitur porttitor, lacus nunc tristique nunc, et ornare ex dolor nec risus. Aliquam erat volutpat. Pellentesque id convallis quam. Proin urna ante, placerat vitae iaculis vel, venenatis at tortor.\r\n\r\nIn rutrum justo mauris, in dictum sapien suscipit in. Vestibulum eget odio bibendum, tincidunt ligula quis, consequat est. Nunc efficitur dictum tincidunt. Etiam sed feugiat nisi. Fusce auctor semper pharetra. Mauris convallis quis nulla a porttitor. Donec bibendum pretium pharetra. Integer malesuada ullamcorper elit, non elementum ipsum ornare at. Nullam leo nunc, faucibus sed dignissim id, scelerisque molestie tellus. Praesent sagittis lacinia libero nec pellentesque. Proin posuere facilisis pulvinar. In hac habitasse platea dictumst.\r\n\r\nVivamus consequat dolor et faucibus efficitur. Integer semper nec eros et cursus. Nunc a condimentum ex. Suspendisse accumsan lobortis bibendum. Quisque at consequat velit. Etiam condimentum metus neque, sit amet fermentum nunc egestas id. Donec aliquet semper egestas. Cras id scelerisque nunc, ac pellentesque lectus.\r\n\r\nQuisque sollicitudin mauris et dolor accumsan malesuada. Aliquam quis mi mollis, tristique leo vel, tristique nibh. Donec a risus ac ligula venenatis auctor et at sem. In non porttitor augue. Nam tincidunt scelerisque justo, vel lobortis urna dapibus ut. Nunc ultricies tellus massa, at semper massa accumsan nec. Ut volutpat lorem urna, ut auctor libero molestie bibendum. In interdum vehicula finibus. Donec convallis sapien a auctor sodales. Nunc faucibus nunc posuere, aliquam massa vel, sodales tortor. Nulla sagittis turpis vitae nisi faucibus tincidunt.","_et_gb_content_width":""},"categories":[5],"tags":[],"_links":{"self":[{"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/posts\/544"}],"collection":[{"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/comments?post=544"}],"version-history":[{"count":11,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/posts\/544\/revisions"}],"predecessor-version":[{"id":1041,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/posts\/544\/revisions\/1041"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/media\/928"}],"wp:attachment":[{"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/media?parent=544"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/categories?post=544"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wpd.ugr.es\/~ecsens\/wp-json\/wp\/v2\/tags?post=544"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}