Category Archives: Anthelmintic

Collision cross section (CCS) as a complementary parameter to characterize human and veterinary drugs

In the context of human and veterinary drugs identification, ion mobility spectrometry (IMS) in combination with mass spectrometry (MS) may provide a relevant complementary piece of information to mass-to-charge ratio (m/z), the so-called collision-cross-section (CCS). Up to now, however, the … Continue reading

Posted in AGL2015-70708-R, Benzimidazoles, Ion mobility, P12-AGR-1647 | Comments Off on Collision cross section (CCS) as a complementary parameter to characterize human and veterinary drugs

Green and simple analytical method to determine benzimidazoles in milk samples by using salting-out assisted liquid-liquid extraction and capillary liquid chromatography

A green and simple multiresidue method using capillary liquid chromatography (CLC) with UV-diode array detection (DAD) has been developed for the determination of sixteen benzimidazoles (BZs) and its metabolites in milk samples. The separation was achieved in <32 min, using a … Continue reading

Posted in AGL2015-70708-R, Benzimidazoles, Capillary HPLC, Milk, P12-AGR-1647, SALLE, UV-vis | Tagged , , | Comments Off on Green and simple analytical method to determine benzimidazoles in milk samples by using salting-out assisted liquid-liquid extraction and capillary liquid chromatography

Ultra-high performance liquid chromatography with fluorescence detection following salting-out assisted liquid–liquid extraction for the analysis of benzimidazole residues in farm fish samples

Ultra-high performance liquid chromatography (UHPLC) coupled with fluorescence detection (FL) has been proposed for the first time to determine thirteen benzimidazoles (BZs) in farmed fish samples. In order to optimize the chromatographic separation, parameters such as mobile phase composition and … Continue reading

Posted in AGL2015-70708-R, Anthelmintic, Aquaculture products, Benzimidazoles, Fluorescence, P12-AGR-1647, SALLE, Sea bass, Sea bream, Trout, UHPLC | Tagged , , | Comments Off on Ultra-high performance liquid chromatography with fluorescence detection following salting-out assisted liquid–liquid extraction for the analysis of benzimidazole residues in farm fish samples

Coupling sweeping-micellar electrokinetic chromatography with tandem mass spectrometry for the therapeutic monitoring of benzimidazoles in animal urine by dilute and shoot.

A new method based on micellar electrokinetic chromatography-tandem mass spectrometry (MEKC-MS/MS) has been developed for the identification and simultaneous quantification of thirteen benzimidazoles in animal urine. In order to obtain an appropriate separation with the highest sensitivity, different electrophoretic parameters … Continue reading

Posted in Anthelmintic, Benzimidazoles, Biological fluids, Dilute and shoot, Electrophoresis, MEKC, Mass spectrometry, P12-AGR-1647, Sweeping, Urine | Tagged , , | Comments Off on Coupling sweeping-micellar electrokinetic chromatography with tandem mass spectrometry for the therapeutic monitoring of benzimidazoles in animal urine by dilute and shoot.

Determination of benzimidazoles in meat samples by capillary zone electrophoresis tandem mass spectrometry following dispersive liquid–liquid microextraction.

A novel method based on capillary zone electrophoresis-tandem mass spectrometry has been proposed and validated for the identification and simultaneous quantification of twelve benzimidazoles in meat samples. Electrophoretic separation was carried out using 500 mM formic acid (pH 2.2) as background … Continue reading

Posted in Benzimidazoles, CZE, DLLME, Mass spectrometry, P12-AGR-1647, Pork muscle | Tagged , , | Comments Off on Determination of benzimidazoles in meat samples by capillary zone electrophoresis tandem mass spectrometry following dispersive liquid–liquid microextraction.

Capillary electrochromatography coupled with dispersive liquid-liquid microextraction for the analysis of benzimidazole residues in water samples

A novel method for the analysis of benzimidazole residues in water samples by capillary electrochromatography-UV detection (290 nm), using laboratory-made packed columns is presented. Capillaries (25 cm packed length×75 µm inner diameter, 34 cm total length, 25.5 cm effective capillary length) were packed with C18 … Continue reading

Posted in Anthelmintic, Benzimidazoles, DLLME, Electrochromatography, P12-AGR-1647, Projects, UV-vis, Water | Tagged , | Comments Off on Capillary electrochromatography coupled with dispersive liquid-liquid microextraction for the analysis of benzimidazole residues in water samples