Category Archives: Tetracyclines

Optimization of a modified QuEChERS method for the determination of tetracyclines in fish muscle by UHPLC–MS/MS.

In this work a sample treatment based on a modified QuEChERS method combined with ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) was proposed to determine the residues of five common tetracyclines in fish muscle samples. The separation was achieved in less … Continue reading

Posted in Mass spectrometry, Panga, QuEChERS, Salmon, Tetracyclines, UHPLC | Tagged , , | Comments Off on Optimization of a modified QuEChERS method for the determination of tetracyclines in fish muscle by UHPLC–MS/MS.

Determination of tetracyclines in human urine samples by capillary electrophoresis in combination with field amplified sample injection.

A sensitive method using CZE‐UV detection has been developed for the determination of five tetracycline antibiotics in human urine samples. To improve the sensitivity of the method, an on‐line preconcentration strategy, named field‐amplified sample injection, has been developed, based on … Continue reading

Posted in CZE, Dilute and shoot, FASI, P12-AGR-1647, Tetracyclines, UV-vis, Urine | Tagged , | Comments Off on Determination of tetracyclines in human urine samples by capillary electrophoresis in combination with field amplified sample injection.

Evaluation of a multiresidue capillary electrophoresis-quadrupole-time-of-flight mass spectrometry method for the determination of antibiotics in milk samples.

A selective and rapid method has been developed to determine 15 antibiotic residues (eight tetracyclines and seven quinolones) in milk samples by capillary zone electrophoresis coupled with quadrupole time-of-flight mass spectrometry (CZE-Q-TOF-MS). The use of this hybrid mass spectrometer allowed … Continue reading

Posted in Antibiotics, CZE, Food, Mass spectrometry, Milk, P12-AGR-1647, Quinolones, SPE, Tetracyclines | Tagged , , | Comments Off on Evaluation of a multiresidue capillary electrophoresis-quadrupole-time-of-flight mass spectrometry method for the determination of antibiotics in milk samples.

Evaluation of a multiresidue capillary electrophoresis-quadrupole-time-of-flight mass spectrometry method for the determination of antibiotics in milk samples.

A selective and rapid method has been developed to determine 15 antibiotic residues (eight tetracyclines and seven quinolones) in milk samples by capillary zone electrophoresis coupled with quadrupole time-of-flight mass spectrometry (CZE-Q-TOF-MS). The use of this hybrid mass spectrometer allowed … Continue reading

Posted in Antibiotics, CZE, Mass spectrometry, Milk, P12-AGR-1647, Quinolones, SPE, Tetracyclines | Tagged , , | Comments Off on Evaluation of a multiresidue capillary electrophoresis-quadrupole-time-of-flight mass spectrometry method for the determination of antibiotics in milk samples.

Salting-out assisted liquid–liquid extraction coupled to ultra-high performance liquid chromatography–tandem mass spectrometry for the determination of tetracycline residues in infant foods

The use of salting-out assisted liquid–liquid extraction (SALLE) combined with ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC–MS/MS) has been evaluated for the determination of tetracyclines in infant foods based on meat and vegetables or in milk. To obtain satisfactory … Continue reading

Posted in Infant foods, Mass spectrometry, P12-AGR-1647, SALLE, Tetracyclines, UHPLC | Tagged | Comments Off on Salting-out assisted liquid–liquid extraction coupled to ultra-high performance liquid chromatography–tandem mass spectrometry for the determination of tetracycline residues in infant foods

Trace determination of tetracyclines in water samples by capillary zone electrophoresis combining off-line and on-line sample preconcentration

In this work, a sensitive and reliable method using capillary zone electrophoresis with UV detection has been developed for trace determination of tetracycline antibiotics in river, spring, and ground waters. A solid-phase extraction method using Oasis HLB was applied for … Continue reading

Posted in CZE, LVSS, P12-AGR-1647, SPE, Tetracyclines, UV-vis, Water | Tagged , | Comments Off on Trace determination of tetracyclines in water samples by capillary zone electrophoresis combining off-line and on-line sample preconcentration